Question: What size breaker do I need for a stove?

The suggested circuit breaker size for the kitchen stove is 50 amps, 220 volts. This is a double breaker. Single breakers normally carry 110 volts. It must be a dedicated circuit for the stove only, meaning that no other appliances or outlets can be served by that circuit.

Can I use a 40 amp breaker for a stove?

According to the NEC, any household cooking appliance rated at 12kW or less can be served by a 40A circuit. Yours is over this so bumping up to a 50A would be required.

Can I use a 40 amp breaker for a 50 amp stove?

3 Answers. In general, no. Installing a 50A breaker on wiring only designed to support 40A is dangerous and can result in a house fire. 40A circuits need #8 copper wire, whereas 50A circuits need #6 copper.

What size breaker do I need for a 220 stove?

Range Electric (posted 2010) - 220 - 240 volt, 60 hertz, properly grounded circuit with 40 amp breaker or fuse protection with #8 gauge wire. With a 50 amp breaker, # 6 gauge wire is required.

Can you run a stove on a 20 amp breaker?

Yes. Electric stoves draw anywhere from 30 to 60 amps on average. This is much more than your typical 20-amp breaker can handle. So it definitely needs to be on its own circuit breaker with enough amperage.

Does a gas stove need a dedicated circuit?

An electric range generally needs a dedicated 240/250-volt, 50-amp circuit. If its a gas range, however, it will only require only a 120/125-volt receptacle to power the range controls and vent hood.

What size wire should I use for a 50 amp breaker?

6 50 AMP Wire Size For a maximum of 50 amps, youll need a wire gauge of 6. Fifty amp breakers are most often used to power many different appliances. However, a kitchen oven can alone require 50 amps. Many electric dryers also require a 50 amp breaker.

Can you plug a gas stove into a regular outlet?

hystat wrote: a gas range plugs into any standard 120V outlet in your kitchen. Any one close enough to the stove area will work as long as the cord on the stove is long enough.